AC Limiter / Solid State Decoupler


 

Download datablad

icon
 

Solid State Decoupler/capasitive AC Limiter

– AC mitigation pipeline AC voltages

– Arrest lightning transients

– Protects operating personnel

– Inhibits AC influenced corrosion

– Neutral to DC pipe/soil potential

polarization cell replacement device with cp equipment - solid state decoupler

Solid state polarization cells or AC grounding devices are used to mitigate pipeline AC voltages resulting from induction from overhead power lines sharing the same corridor. A main purpose of the AC limiting devices is to protect operating personnel from hazardous touch voltages and second to conduct ac current from the pipeline to soil, lowering the voltage.

Balanced AC limiting

An increasingly important task for the AC mitigation/limiting device is to inhibit AC influenced corrosion by lowering the pipe to soil AC voltage. CP experts throughout have reached agreement that excessive cathodic protection combined with AC voltage is a non-tolerated mixture, likely to cause accelerated AC corrosion. The AC discharge devise has been designed and developed for the purpose of being close to neutral to the DC thus to maintain the rectifier in full control of the cathodic protection level. Unlike other known solid state decouplers, who focuses on polarization cell replacement, it does not produce additional cathodic polarization by rectifying some of the AC voltage.